Anti-Pass-Back
I. Single-door
Available
Access Mode:
B. Card only / Card or PIN /
FP or Card or PIN
One Slave WG Reader (Option) One Host RS-485 Reader (Option)








1.
ACC995
anti-pass-back setting
a.
Enable
device
Access programming mode → 4. Parameter (2) → 7. Anti-passback → Input: 1 or 2 Enable/Disable Anti-pass-back: 1. Yes, 2. NO → Input: 1 or 2 as indoor or outdoor reader: 1. Indoor, 2.Outdoor
b.
Enable
card user
By ACC995 hardware
Access programming mode → 1. Add/Delete → 9. Antipass Group → Input 5 digits start address: 00001~01023 (User address) → Input 5 digits end address: 00001~01023 (User address)
By 701Client software
G. F. E. D. C. B . A.

![]()
![]()


![]()

![]()


A.
Tick the anti-pass-back function
B.
Press the Tool icon and select Card
Copy
C.
Input a range of user address you want
to use the same setting. For example: Copy data of User address (number) 00001
to 00020
D.
Tick the setting you want to copy to
other user
Access Mode including

E.
Press Yes
F.
Save
G.
Exit the User Card Edit window
C. B. A.
![]()



![]()

A.
Press the “Download” icon on the tool
bar of 701Client
B.
Tick the target control you want to
download
C.
Press “User Card” to download all user
data to target controller
1.
ACC950
anti-pass-back setting
(As same as ACC995)
2.
ACC900
a.
ACC900
anti-pass-back setting
(1)
Device enable
Access programming mode → 20*128# please refer to “20*DDD#”
function default value for additional function value
(2)
Card
user enable
Access programming mode → 26*SSSSS*EEEEE*1# (i.e. User address from 00001 to 00005 enable the anti-pass-back function:
26*00001*00005*1#
b.
ACC900
access mode setting
(1)
Card
or PIN
Access programming mode *123456# or *Master Code# (If already changed) → 12*UUUUU*PPPP# (i.e. User address: 00001 and PWD: 1234,
input 12*00001*1234#)
(2) Card
and PIN
Access programming mode *123456# or *Master Code# (If already changed) → 13*UUUUU*PPPP# (i.e. User address: 00001 and PWD: 1234,
input 13*00001*1234#)
B. PIN only
One Slave WG Keypad Reader One Host RS-485 Reader (Option)





C. Card and PIN
One Host RS-485 Reader (Option) One Slave WG Keypad Reader




II.
Dual-door (For ACC900 only)
Normally used on
parking lot system. ACC900 will become a
controller and be hided/installed at the control center.
Two Slave WG Readers One Host RS-485 Reader




ACC900WR WG format setting
WG FormatWire Color |
WG34
|
WG34+4 |
|
Yellow |
Close
to GND |
Close
to GND |
Brown
|
Open |
Close
to GND |
III.
Multi-door (Under ECL-ACC1000)
Each 18
readers of ACC1000 (16 RS-485 readers + 2 WG readers) could be designated as
indoor reader or outdoor reader. For
example: 4 indoor readers but 14 outdoor readers.
B.
CH1: 8 Units of Slave RS-485
Reader (Node 1 to 8) CH2: 8 Units of Salve RS-485
Reader ((Node 9 to 16)
Card Only /Card
or PIN
Two Slave WG Readers (Option) Node: 17 to 18









C. PIN Only
Card and PIN